Northwestern University Feinberg School of Medicine

Northwestern University Prosthetics-Orthotics Center

Papers and Presentations of 1994

Papers

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation Of The Effect That The Otto Bock 3R36 Habermann 4 - Bar Linkage Knee (Most Stable Alignment) Has On Swing Phase Floor Clearance. Internal Technical Report Number 001, Northwestern University Prosthetics Research Laboratory, 5 December 1994.

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation of the Effect that the Otto Bock 3R36 Habermann 4 - Bar Linkage Knee (Least Stable Alignment) has on Swing Phase Floor Clearance. Internal Technical Report Number 002, Northwestern University Prosthetics Research Laboratory, 5 December 1994.

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation of the Effect that the Otto 3R23 Knee Disarticulation 4 - Bar Linkage Knee has on Swing Phase Floor Clearance. Internal Technical Report Number 003, Northwestern University Prosthetics Research Laboratory, 5 December 1994.

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation of the Effect that the Otto Bock 3R70 (Most Stable Alignment) 4 - Bar Linkage Knee has on Swing Phase Floor Clearance. Internal Technical Report Number 004, Northwestern University Prosthetics Research Laboratory, 7 December 1994.

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation of the Effect that the Otto Bock 3R70 (Least Stable Alignment) 4 - Bar Linkage Knee has on Swing Phase Floor Clearance. Internal Technical Report Number 005, Northwestern University Prosthetics Research Laboratory, 7 December 1994.

Gard, S.A., Childress, D.S., and Uellendahl, J.E., An Investigation of the Effect that the Otto Bock 3R60 4 - Bar Linkage Knee has on Swing Phase Floor Clearance. Internal Technical Report Number 006, Northwestern University Prosthetics Research Laboratory, 7 December 1994.

Presentations

Childress, D.S., Edwards, M., Fenwick, L., Northwestern University Prosthetic-Orthotic Center: The Education Program in Orthotics and Prosthetics, Proceedings of the 20th Annual Meeting & Scientific Symposium, March 23-26, 1994, Nashville, TN, p. 71.

Rovick, J., Uellendahl, J., A Plastic Deposition Fabricator for the CAM of Sockets: Material Strengths and Clinical Experience, Proceedings of the 20th Annual Meeting & Scientific Symposium of AAOP, Nashville, TN, p. 54, March 23-26, 1994

Uellendahl, J.E., Heckathorne, C.W., Control Schemes for Upper Limb Prostheses, Proceedings of the AAOP 20th Annual Meeting & Scientific Symposium, p. 48, March 23-26, 1994, Nashville, TN.